Nortel Networks 1000 User Manual
Page 296

296
NT5D33 and NT5D34 Lineside E1 Interface cards
Figure 68
Set Mode (S M): Table screen
Idle SEND – This is the value that the LEI sends (acting as the CO or
PSTN) when the circuit is in the idle state. This value is required.
Idle RECEIVE – This is the value that the LEI expects to see from the
CPE when it is in the idle state. This value is required.
Blocking RECEIVE – This is the value that the LEI expects to see from
the CPE when the customer equipment is in the blocking or fault state
and is unable to accept new calls. Set this value to N if this state is
not needed. If this value is not set to N, then dip switch #2 position 6
determines whether off-hook or on-hook is sent to the M1/SL100 when this
state is entered. See
Table 104 "LEI card - E1 Switch 2 (S2) dip switch
Nortel Communication Server 1000