Signaling interface, Carrier interface – Nortel Networks 1000 User Manual
Page 838
![background image](/manuals/193391/838/background.png)
838
NTAK79 2.0 Mb PRI card
Table 354
Digital pad values and offset allocations (cont’d.)
PAD SET 0
PAD SET 1
Offset
PAD
Offset
PAD
10
10.0 dB
10
–10.0 dB
11
11.0 dB
11
spare
12
12.0 dB
12
spare
13
13.0 dB
13
spare
14
14.0 dB
14
Idle Code
15
spare
15
Unassigned Code
Signaling interface
The signaling interface consists of the A07 DS-30X signaling controller.
This interface provides an 8 Kbps signaling link through the DS-30X
timeslot zero data bit zero. Messages are 3 bytes in length.
The Meridian 1 signaling interface consists of the A07 DS-30X signaling
controller. This interface provides an 8 Kbps signaling link via the DS-30X
timeslot zero data bit zero. Messages are 3 bytes in length.
The signaling interface consists of the A07 DS-30X signaling controller.
This interface provides an 8 Kbps signaling link through the DS-30X
timeslot zero data bit zero. Messages are 3 bytes in length.
Carrier interface
The E1 interface connection to the external digital carrier is provided by
the line interface chip. This chip provides accurate pulse shaping to meet
the CCITT pulse mask requirements. It provides clock recovery functions
on the receive side as well as tolerance to jitter and wander in the received
bit stream.
For the E1 interface, the connection to the external digital carrier is
provided by the line interface chip. This device provides accurate pulse
shaping to meet the CCITT pulse mask requirements. It provides clock
recovery functions on the receive side as well as tolerance to jitter and
wander in the received bit stream.
The E-1 interface connection to the external digital carrier is provided by
the line interface chip. This chip provides accurate pulse shaping to meet
the CCITT pulse mask requirements. It provides clock recovery functions
on the receive side as well as tolerance to jitter and wander in the received
bit stream.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008