Alarm operation and reporting

The MMI monitors the T1 link according to the parameters established
through the Set Alarm command set for the following conditions:

Excessive bit error rate

Frame slip errors

Out of frame condition

Loss of signal condition

Blue alarm (AIS) condition

Descriptions of the excessive bit error rate and frame slip errors conditions
can be found in

“Configuring parameters” (page 227)

. Bit errors may

activate either a level 1 or level 2 alarm. The remaining conditions, when
detected, always cause the system to activate a level 2 alarm.

An out of frame condition is declared if two out of four frame bits are
in error. If this condition occurs, the hardware immediately attempts to
reframe. During the reframe time, the T1 link is declared out of frame, and
silence is sent on all receive timeslots.

A loss of signal condition is declared if a full frame (192 bits) of
consecutive zeros has been detected at the receive inputs. If this condition
occurs, the T1 link automatically attempts to resynchronize with the distant
end. If this condition lasts for more than two seconds, a level 2 alarm is
declared and silence is sent on all receive timeslots. The alarm is cleared
if, after two seconds, neither a loss of signal, out of frame condition, nor
blue alarm condition occurs.

If a repeating device loses signal, it immediately begins sending an
unframed all 1’s signal to the far-end to indicate an alarm condition. This
condition is called a blue alarm, or an Alarm Indication Signal (AIS). If an
AIS is detected for more than two seconds, a level 2 alarm is declared,
and silence is sent on all receive timeslots. The alarm is cleared if, after
two seconds, neither a loss of signal, out of frame condition, nor blue
alarm condition occurs.