beautypg.com

T1 channel specifications, Power requirements – Nortel Networks 1000 User Manual

Page 177

background image

Electrical specifications

177

Table 66
Lineside T1 card - line interface unit electrical characteristics (cont’d.)

Characteristics

Description

Signaling

Loop or ground start A/B robbed-bit

Distance to Customer Premise
Equipment (CPE) or Channel Service
Unit

0-199.6 meters (0–655 feet)

Table 67 "Lineside T1 card - line interface unit electrical characteristics"
(page 177)

provides a technical summary of the T1 line interfaces,

and

Table 69 "Lineside T1 card - power required" (page 178)

lists the

maximum power consumed by the card.

T1 channel specifications

Table 67 "Lineside T1 card - line interface unit electrical characteristics"
(page 177)

provides specifications for the 24 T1channels. Each

characteristic is set by dip switches. See

“Installation and configuration”

(page 179)

for the corresponding dip switch settings.

Table 67
Lineside T1 card - line interface unit electrical characteristics

Characteristics

Description

Framing

ESF or D4

Coding

AMI or B8ZS

Signaling

Loop or ground start A/B robbed-bit

Distance to Customer Premise
Equipment (CPE) or Channel Service
Unit

0-199.6 meters (0–655 feet)

Power requirements

The Lineside T1 card requires +15 V, –15 V, and +5 V from the backplane.
One NT8D06 IPE Power Supply AC or NT6D40 IPE Power Supply DC
can supply power to a maximum of eight Lineside T1 cards. See

Table 68

"Lineside T1 card - power required" (page 177)

.

Table 68
Lineside T1 card - power required

Voltage

Current (max.)

+ 5.0 V dc

1.6 Amp

+15.0 V dc

150 mA.

–15.0 V dc

150 mA.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008