NT5D11 and NT5D14 Lineside T1 Interface cards
Figure 35
Lineside T1 card - connecting two or more cards to the MMI
To make the connections at the MDF, follow this procedure:
Step
Action
1
Punch down the first eight pairs of a standard telco 25-pair
female-connectorized cross-connect tail starting with the first tip
and ring pair of the Lineside T1 motherboard card slot on the
cross-connect side of the MDF terminals.
2
Plug the NT5D13AA Lineside T1 I/O cable into this 25-pair
cross-connect tail at the MDF, regardless of the card slot
restrictions that exist from the vintage level of IPE or CE/PE
module used. This connection can also be made at the
MDF without using the NT5D13 Lineside T1 I/O cable, by
cross-connecting according to the pinouts in
T1 card - backplane pinouts" (page 203)
3
Turn over the T1 transmit and receive pairs, where required
for hardwiring the Lineside T1 card to local CPE T1 terminal
equipment.
--End--