Installation and configuration – Nortel Networks 1000 User Manual
Page 179
Installation and configuration
179
Table 71
Lineside T1 card - environmental specifications
Parameter
Specifications
Operating temperature-normal
15
to +30
C (+59
to 86
F), ambient
Operating temperature-short term
10
to +45
C (+50
to 113
F), ambient
Operating humidity-normal
20% to 55% RH (non-condensing)
Operating humidity-short term
20% to 80% RH (non-condensing)
Storage temperature
–50
to +70
C (–58
to 158
F), ambient
Storage humidity
5% to 95% RH (non-condensing)
Table 72 "Lineside T1 card - environmental specifications" (page 179)
lists
the environmental specifications of the Lineside T1 card.
Table 72
Lineside T1 card - environmental specifications
Parameter
Specifications
Operating temperature-normal
15
to +30
C (+59
to 86
F), ambient
Operating temperature-short term
10
to +45
C (+50
to 113
F), ambient
Operating humidity-normal
20% to 55% RH (non-condensing)
Operating humidity-short term
20% to 80% RH (non-condensing)
Storage temperature
–50
to +70
C (–58
to 158
F), ambient
Storage humidity
5% to 95% RH (non-condensing)
Installation and configuration
Installation and configuration of the Lineside T1 card consists of six basic
steps:
Step
Action
1
Configure the dip switches on the Lineside T1 card for the
environment.
2
Install the Lineside T1 card into the selected card slots in the
IPE shelf.
3
Cable from the I/O panel to the Customer Premise Equipment
(CPE) or CSU, MMI terminal or modem (optional), external alarm
(optional), and other Lineside T1 cards for daisy chaining use of
MMI terminal (optional).
4
Configure the MMI terminal.
5
Configure the Lineside T1 card through the system software and
verify self-test results.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.