beautypg.com

Installation and configuration – Nortel Networks 1000 User Manual

Page 179

background image

Installation and configuration

179

Table 71
Lineside T1 card - environmental specifications

Parameter

Specifications

Operating temperature-normal

15

to +30

C (+59

to 86

F), ambient

Operating temperature-short term

10

to +45

C (+50

to 113

F), ambient

Operating humidity-normal

20% to 55% RH (non-condensing)

Operating humidity-short term

20% to 80% RH (non-condensing)

Storage temperature

–50

to +70

C (–58

to 158

F), ambient

Storage humidity

5% to 95% RH (non-condensing)

Table 72 "Lineside T1 card - environmental specifications" (page 179)

lists

the environmental specifications of the Lineside T1 card.

Table 72
Lineside T1 card - environmental specifications

Parameter

Specifications

Operating temperature-normal

15

to +30

C (+59

to 86

F), ambient

Operating temperature-short term

10

to +45

C (+50

to 113

F), ambient

Operating humidity-normal

20% to 55% RH (non-condensing)

Operating humidity-short term

20% to 80% RH (non-condensing)

Storage temperature

–50

to +70

C (–58

to 158

F), ambient

Storage humidity

5% to 95% RH (non-condensing)

Installation and configuration

Installation and configuration of the Lineside T1 card consists of six basic
steps:

Step

Action

1

Configure the dip switches on the Lineside T1 card for the
environment.

2

Install the Lineside T1 card into the selected card slots in the
IPE shelf.

3

Cable from the I/O panel to the Customer Premise Equipment
(CPE) or CSU, MMI terminal or modem (optional), external alarm
(optional), and other Lineside T1 cards for daisy chaining use of
MMI terminal (optional).

4

Configure the MMI terminal.

5

Configure the Lineside T1 card through the system software and
verify self-test results.

Nortel Communication Server 1000

Circuit Card Reference

NN43001-311

02.06

Standard

27 August 2008

Copyright © 2003-2008 Nortel Networks

.