Man-Machine E1 maintenance interface software

305

however, the

STOP

command terminates a test set to any duration from

one to 99. After entering the test number, a prompt similar to

Figure 76

"Test parameters screen" (page 305)

appears.

Figure 76
Test parameters screen

Before a test is run, be sure to verify that the card is disabled, as the tests
interfere with calls currently in process.

During a test, if an invalid word is received, this is recorded by a failure
peg counter. The peg counter has a limit of 65,000. At the end of the test,
the Test Results message indicates how many failures, if any, occurred
during the test.

Table 113 "MMI Tests" (page 305)

shows which test to run for the

associated equipment.

Table 113
MMI Tests

Test number

Equipment Tested

Test Description

1

LEI

Local loopback

2

E1 link, LEI, and E1
network

External loopback

3

CPE device and E1
network

Network loopback

Test 1, local loopback, loops the E1 link signaling toward itself at the
backplane connector. Test data is generated and received on all timeslots.
If this test fails, it indicates that the LEI is defective.

Figure 77 "MMI Local

loopback test" (page 306)

illustrates how the signaling is looped back

toward itself.