Nortel Networks 1000 User Manual
Page 91
NT8D14 Universal Trunk card
91
Jumper strap settings
Trunk types
Loop length
J1.X
J2.X
J3.X
J4.X
RAN: continuous
operation mode
Paging
Not applicable: RAN and
paging trunks should not
leave the building.
Note: Jumper strap settings J1.X, J2.X, J3.X, and J4.X apply to all eight units; "X" indicates the
unit number, 0–7. "Off" indicates that no jumper strap is installed on a jumper block. Store unused
straps on the universal trunk card by installing them on a single jumper pin as shown below:
Table 30
NT8D14 vintages BA/BB jumper strap settings-extended range
Jumper strap settings
Trunk types
Loop length
J1.X
J2.X
J3.X
J4.X
CO/FX/WATS
2-way tie (LDR)
2-way tie (OAID)
> 1524 m (5000 ft)
Off
Off
1–2
2–3
DID
> 600 ohms
On
On
1–2
2–3
RAN: pulse start or level
start modes
Not applicable: RAN
trunks should not leave
the building.
Off
Off
2–3
1–2
Note: Jumper strap settings J1.X, J2.X, J3.X, and J4.X apply to all eight units; "X" indicates the unit
number, 0–7. "Off" indicates that no jumper strap is installed on a jumper block.
Table 31
NT8D14 vintages BA/BB trunk types-termination impedance and balance network
Balance network for loop lengths (Note 2)
Trunk types
Terminating
impedance
(Note 1)
Zero–915 m
(zero–3000 ft)
915–1524 m
(3000–5000 ft)
> 1524 m
(> 5000 ft)
CO/FX/WATS
600 or 900 ohms
600 ohms
3COM1
3COM2
2-way tie (LDR)
600 or 900 ohms
600 ohms
3COM1
3COM2
2-way tie (OAID)
600 or 900 ohms
600 ohms
3COM1
3COM2
DID (loop < 600
ohms)
600 or 900 ohms
600 ohms
3COM1
3COM2
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311
02.06
Standard
27 August 2008