Manually enabled, System disabled – Nortel Networks 1000 User Manual
Page 403

Maintenance
403
Figure 105
MSDL states
A newly configured MSDL automatically enters the manually disabled
state. An operating MSDL can be manually disabled by issuing the
DIS
MSDL x
command in LD 37 (step 1 in
Figure 105 "MSDL states" (page
).
Entering the
DIS MSDL x
command in LD 37 moves the card to manually
disabled status and stops all system communication with the card (step 5
in
Figure 105 "MSDL states" (page 403)
).
Manually enabled
When the card has been manually disabled, re-enable it with the
ENL
MSDL x
command in LD 37 (step 2 in
Figure 105 "MSDL states" (page
).
System disabled
When the system disables the MSDL card (step 4 in
), it continues to communicate and attempt maintenance
procedures on the card. To stop all system communication with the
card, enter
DIS MSDL x
to disable it (step 5 in