53

MAESTRO User Manual

Section 2 — The Maestro Configuration Editor

IP Address

1.

Enter the IP address for the control system. For example:

For Encore, enter the IP address of the primary System Control
Board (SCB). This entry will typically be an “EN1” (Encore facility
LAN) address. This address was defined during Encore configura-
tion.

For Prelude, enter the IP address of the primary Prelude Control
panel.

For Jupiter, enter the IP address of the Jupiter file server PC. This
address was defined during Jupiter configuration.

2.

Select the

Apply

button

(to leave the table open) or the

OK

button (to close

the table). If there are entry errors (such as blank fields) they will be
indicated at this time.

3.

Notice that when this table is completed, the control system server IP is
indicated along the top of the editor screen and the

Connect to Server

button is enabled. By selecting

Connect to Server

the editor will retrieve

configuration data already entered on the router control system.

4.

Continue by selecting another table to edit, or Save the set as built so
far by selecting “File > Save As” and creating a name for the
configuration set. This filename must follow standard Windows
filename rules. As a convention, you may wish to name the set “[Station
ID]-[Date of Creation or Edit].” For example, “WXYZ-10-APR-08.”

After all the configuration tables are edited and saved you must “com-
pile” the set before it can be downloaded using the Deployment
Control Center.

5.

Set the Configuration file’s management options by selecting
Properties from the File menu (File > Properties). This step will open
the dialog that is shown in

Figure 17

.

Figure 17. Properties Menu