beautypg.com

Grass Valley Maestro Master Control v.2.4.0 User Manual

Page 123

background image

119

MAESTRO User Manual

Section 2 — The Maestro Configuration Editor

In general, the MI-3040 must be established as an MPK device for tally use,
after which it is referred to as an “MI-3040T.” The Jupiter Tally Relay and
Tally Dependency tables must also be filled in, as described in the Jupiter
manual.

Special Notes for Jupiter Configuration

MPK Devices Table

Enter the MI-3040 as described in the Jupiter manual. There is no entry
for a device of type “MCS_TLY.”

Tally Relay Table

Make an entry for each tally light, as described in the manual.

Tally Dependency Table

For the Tally Dependency Table, refer to the section “Configuration for
Systems with a Non-Saturn Master Control Switcher.”

Each Opto-Isolator input of the MI- 3040 is associated in this table with
the corresponding router output. For example, if Maestro “Bus A” has
been associated with GPIO 1 (as shown on

page 117

), and GPIO 1 has

been wired to MI-3040 opto 0, then the Tally Dependency Table will be
used to associate opto 0 with the router output that is wired to Bus A.