438

Electrical

4 RU Frame

Air intake is on the left, exhaust on the right.

Electrical

Unless specified otherwise, the following specifications apply to a single
channel (i.e., one video plus associated audio channels)

Table 14. Electrical Specifications

Power

8 RU Maestro/Concerto Frame

100-240 V, 10-5 A, 50/60 Hz, auto-sensing

4 RU Maestro/Concerto Frame

100-240 V, 5-2.5 A, 50/60 Hz, auto-sensing

Hardware Control Panels

MAE-4X2STD-CP

100-240 V, 0.5-0.2 A, 50/60 Hz, auto-sensing

MAE-5X2STD-CP

100-240 V, 0.6-0.25 A, 50/60 Hz, auto-sensing

Touch Screen (GUI) PC

Antec SP-450 Power Supply: 115 V, 9 A / 230 V, 5 A (manual voltage
adjustment required). 50/60 Hz

Touch Screen (GUI) Monitor

100-240 V, 0.7-0.35 A, 50/60 Hz, auto-sensing

Video Standards

Interlaced Scan

1080/I, 59.94 Hz, 16x9 HD
(ATSC)

SMPTE 274M-2005, ATSC Table 3 @ 1.5 Gb/s

1080/I, 50 Hz, 16x9 HD

SMPTE 274M-2005 @ 1.5 Gb/s

575/I, 50 Hz, 4x3 SD (PAL)

BT.601-4 (normal 625/50 @ 270 Mb/s)

480/I, 59.94 Hz, 4x3 SD
(NTSC)

SMPTE 125M, SMPTE 259M, ATSC Table 3,
(normal 525/60 @ 270 Mb/s)

Progressive Scan

720/P, 59.94 Hz, 16x9 HD
(ATSC)

SMPTE 296M-2001, ATSC Table 3 @ 1.5 Gb/s

720/P, 50 Hz, 16x9 HD

SMPTE 296M-2001

Transport

SMPTE 259M*, SMPTE 292M

*Except rise and fall times are according to SMPTE 292M

Video Reference

SD Operation

Analog black burst (preferred). Must be compatible with input video stan-
dard (as listed above). Although any constant APL color test signal may be
used for SD sync, the preferred reference signal is analog black burst.

HD Operation

Analog black burst preferred. Use of HD tri-level sync (as appropriate for
video standard) is acceptable but does not support VITC or 10-field ID