3GPP TS 27.007 AT COMMANDS
87
HSPA+ AT Commands Reference Guide
Parameters and Values
Current alarm time as quoted string.
“”
Empty string. Deletes the current alarm and resets all the +CALA
parameters to the default configuration.
"hh:mm:ss±zz"
Format used only when issuing +CALA with parameter
"yy/MM/dd,hh:mm:ss±zz"
Generic format: it’s the same as defined for +CCLK.
Index of the alarm.
0
The only value supported is 0
Alarm behavior type
0
Reserved for other equipment use
1
The module simply wakes up fully operative as if the ON/OFF
button had been pressed. If the device is already ON at the alarm
time, then it does nothing. Default .
2
The module wakes up in "alarm mode" if at the alarm time it was
off, otherwise it remains fully operative. In both cases the module
issues an unsolicited code every 3 seconds.
+CALA:
where
The device keeps on sending the unsolicited code every 3 seconds
until a #WAKE command is received or a 90 seconds timer expires.
If the device is in "alarm mode" and it does not receive the #WAKE
command within 90 seconds then it shuts down.
3
The module wakes up in "alarm mode" if at the alarm time it was
off, otherwise it remains fully operative. In both cases the module
starts playing the alarm tone on the selected path for the ringer.
See command #SRP.
The device keeps playing the alarm tone until a #WAKE command is
received or a 90 second time‐out occurs. If the device is in "alarm
mode" and it does not receive the #WAKE command within 90
seconds then it shuts down.
4
The module wakes up in "alarm mode" if at the alarm time it was
off, otherwise it remains fully operative. In both cases the module
brings the pin GPIO6 high, provided its
output, and keeps it in this state until a #WAKE command is
received or a 90 seconds timer expires. If the device is in "alarm
mode" and it does not receive the #WAKE command within 90
seconds then it shuts down.
5
The module makes both the actions as for type=2 and
6
The module makes both the actions as for type=2 and
7
The module makes both the actions as for type=3 and
8
The module wakes up in "alarm mode" if at the alarm time it was
off, otherwise it remains fully operative. In both cases the module
sets High the RI output pin. The RI output pin remains High until
next #WAKE issue or until a 90 second timer expires. If the device is
in "alarm mode" and it does not receive the #WAKE command
within 90 seconds. After that it shuts down.
Unsolicited alarm code text string. It has meaning only if
equal to 2, 5 or 6.