AUDIO COMMANDS 

 

 

311 

HSPA+ AT Commands Reference Guide

 

Examples 

AT#TSVOL=64,1,5

OK

AT#TSVOL?

#TSVOL:1,0

#TSVOL:2,0

#TSVOL:4,1,5

#TSVOL:8,0

#TSVOL:16,1,5

#TSVOL:32,0

#TSVOL:64,1,5

#TSVOL:128,0

OK

User Defined Tone SET   #UDTSET command 

Set command sets frequency and amplitude composition for a user‐defined tone. 

Read command returns the current settings for the tones: 

#UDTSET: G,,,,,, 

#UDTSET: H, ,,,,, 

#UDTSET: I, ,,,,, 

#UDTSET: J, ,,,,, 

#UDTSET: K, ,,,,, 

#UDTSET: L, ,,,,, 

Test command returns the supported range of values for  and 

Syntax 

Command 

Command type 

AT#UDTSET= ,,[,,[,,]] Set 

AT# UDTSET? 

Read 

AT# UDTSET =? 

Test 

Parameters and Values 

 

Tone index (G,H,I,J,K,L). 

 

Frequency in Hz. Range: (300,3000) in step of 1 Hz. 

 

Amplitude in dB. Range: (10,100) in step of 1 dB.