Clock management #cclk, Syntax, Parameters and values – Synaccess Networks NP-0801DTM User Manual
Page 182: Notes, Examples, Enhanced network selection #ens

CUSTOM AT COMMANDS
HSPA+ AT Commands Reference Guide
182
Clock Management #CCLK
Set command sets the real‐time clock of the ME.
Read command returns the current setting of the real‐time clock, in the format
Test command returns the OK result code.
Syntax
Command
Command type
AT#CCLK=
Set
AT#CCLK?
Read
AT#CCLK=?
Test
Parameters and Values
Current time as quoted string in the format: "yy/MM/dd,hh:mm:ss±zz,d".
yy
Year. Two last digits are mandatory. Range is 00‐99.
MM
Month. Two last digits are mandatory. Range is 01‐12.
dd
Day. Two last digits are mandatory.
The range for dd(day) depends on the month and the year it refers to. Available
ranges are:
(01‐28)
(01‐29)
(01‐30)
(01‐31)
Trying to enter an out of range value raises an error.
hh
Hour. Two last digits are mandatory. Range is 00‐23.
mm
Minute. Two last digits are mandatory. Range is 00‐59.
ss
Seconds. Two last digits are mandatory. Range is 00‐59.
±zz
Time zone. Indicates the difference, expressed in quarter of an hour, between the
local time and GMT. Two last digits are mandatory. Range is ‐47 to +48.
d
Number of hours added to the local time zone because of daylight savings time
adjustment. Range is 0‐2.
Notes
If the time is set by the network but the DST information is missing, or the time is set by +CCLK command, then
the
Examples
AT#CCLK="02/09/07,22:30:00+04,1"
OK
AT#CCLK?
#CCLK: 02/09/07,22:30:25+04,1
OK
Enhanced Network Selection #ENS
Set command activates the ENS functions.