HAYES COMPLIANT AT COMMANDS
HSPA+ AT Commands Reference Guide
24
V.250 AT Commands
Generic Modem Control
Set to Factory‐Defined Configuration &F
Execute this command to set the configuration parameters to default values specified by the manufacturer. This
includes hardware configuration switches and other manufacturer‐defined criteria.
Syntax
Command
Command type
AT&F[
Set
Parameters and Values
Hardware version, a string of no more than 31 characters.
0
Only the factory profile base section parameters are set to default values.
1
Full factory profile restored, that is, the factory profile base section and the
extended section are restored.
Notes
If parameter
Reference: V.25ter.
Soft Reset Z
Execute this command to the base section of the specified user profile and the extended section of the default
factory profile.
Syntax
Command
Command type
ATZ[
Parameters and Values
Hardware version, a string of no more than 31 characters.
0‐1
User profile number.
Notes
Any call in progress is terminated.
If parameter
Reference: V.25ter.