Parameters and values, Notes, Response formatting character s4 – Synaccess Networks NP-0801DTM User Manual
Page 41: Syntax, Command line editing character s5

HAYES COMPLIANT AT COMMANDS
41
HSPA+ AT Commands Reference Guide
Parameters and Values
Command line termination character (decimal ASCII).
0‐127
Default: 13 (ASCII
Note:
The “previous” value of S3 is used to determine the command line
termination character for entering the command line containing the S3 setting
command. However the result code issued uses the “new” value of S3, as set
during the processing of the command line.
Notes
Reference: V.25ter
Response Formatting Character S4
Set command sets the value of the character generated by the device as part of the header, trailer, and terminator
for result codes and information text, along with the S3 parameter.
Read command returns the current value of S4 parameter. The format of the numbers in output is always 3 digits,
left‐filled with 0s.
Syntax
Command
Command type
ATS4=[
Set
ATS4?
Read
Parameters and Values
Response formatting character (decimal ASCII).
0‐127
Default: 10 (ASCII LF).
Notes
If the value of S4 is changed in a command line the result code issued in response of that command line uses the
new value of S4.
Reference: V.25ter.
Command Line Editing Character S5
Set command sets the value of the character recognized by the device as a request to delete from the command
line the immediately preceding character.
Read command returns the current value of S5 parameter. The format of the numbers in output is always 3 digits,
left‐filled with 0s.
Syntax
Command
Command type
ATS5=[
Set
ATS5?
Read