Parameters and Values
Defines how the STAT_LED GPIO is handled.
0
GPIO tied low.
1
GPIO tied high.
2
GPIO handled by Module Software. Default: 2.
3
GPIO is turned on and off alternatively, with period defined by the sum
Duration of period in which STAT_LED GPIO is tied high while
1‐100
In tenth of seconds. Default: 10.
Duration of period in which STAT_LED GPIO is tied low while
1‐100
In tenth of seconds. Default: 10.
Notes
Values are saved in non‐volatile memory by command #SLEDSAV.
At module boot the STAT_LED GPIO is always tied high and holds this value until the first non‐volatile memory
reading.
To have STAT_LED operative, the first time enter AT#GPIO=1,0,2 setting the GPIO1 as alternate function.
Save STAT_LED GPIO Setting #SLEDSAV
Execute command saves STAT_LED setting in non‐volatile memory.
Test command returns OK result code.
Syntax
Command
Command type
AT#SLEDSAV
Execute
AT#SLED=?
Test
SMS Ring Indicator #E2SMSRI
Set command enables or disables the ring indicator (RI) pin response to an incoming SMS message. If enabled, a
negative going pulse is generated on receipt of an incoming SMS message. The duration of this pulse is
determined by the value of
Read command reports the duration in ms of the pulse generated on receipt of an incoming SM, in the format:
#E2SMSRI:
Note: Value
Test command reports the range of supported values for parameter
Syntax
Command
Command type
AT#E2SMSRI=[
Set
AT#E2SMSRI?
Read
AT#E2SMSRI=?
Test