p366
The upper left of the screen controls the ATR Search, and the upper right controls the PowerSearch. The Work area
angle ranges apply to both searches. The Show button will show the two positions of the search window, first by
moving immediately to Position 1. You will be prompted to press OK to see Position 2. Having defined a “window” of
searching, Center will move that window to a new center position. You will be prompted to “Sight on Centered Position
and Press OK”. The Define button prompts you to shoot the lower left and upper right positions, which are then
displayed above under “Work Area”. If the Work Area is set to start at 0.0000 horizontal, for example, searching would
send the instrument to the backsight point.
Tracking
The instrument can also easily switchin between tracking and non-tracking mode from the store points screen by
toggling the icon of the man in the upper right hand corner. In the image below, we are in tracking mode.
Next the icon has been toggled to non-tracking mode, which can be energy saving. No distances are taken in this mode.