fwFruCfg

2

fwFruCfg

Displays or modifies FRU state alert configuration.

SYNOPSIS

fwfrucfg [--show]

DESCRIPTION

Use this command to configure states and actions for field-replaceable units (FRUs) and small
form-factor pluggables (SFPs). Based on these configuration settings, Fabric Watch generates actions
when a FRU or SFP state changes. For SFPs, Fabric Watch monitors state changes in following events:
SFP inserted, SPP removed, SFP faulty. When used without operand, this command interactively
prompts for user input. To configure email alerts, use fwMailCfg. This command is not applicable to
platforms that do not support FRUs or SFPs.

NOTES

This command requires a Fabric Watch license.

The OFF state (8) is only applicable to FANs on the Brocade DCX and DCX-4S chassis and on the
Brocade 5300 switch.

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

OPERANDS

This command has the following operand:

--show

Displays the current FRU configuration setting. This operand is optional; if
omitted, the configuration prompt displays.

EXAMPLES

To change the FRU state alert configuration:

switch:admin> fwfrucfg

The current FRU configuration:
Alarm State Alarm Action
-----------------------------------------------
Slot 1 1
Power Supply 1 1
Fan 1 1
WWN 1 1
SFP 0 0

Note that the value 0 for a parameter means that
it is NOT used in the calculation

Configurable Alarm States are:
Absent-1, Inserted-2, On-4, Off-8, Faulty-16

Configurable Alarm Actions are:
Errlog-1, E-mail-16
Slot Alarm State: (0..31) [1]
Slot Alarm Action: (0..17) [1]
Power Supply Alarm State: (0..31) [1]
Power Supply Alarm Action: (0..17) [1]
Fan Alarm State: (0..31) [1]