Cfgadd – Dell POWEREDGE M1000E User Manual
Page 131
Fabric OS Command Reference
103
53-1002746-01
cfgAdd
2
cfgAdd
Adds a member to a zone configuration.
SYNOPSIS
cfgadd "cfgName", "member[; member...]"
DESCRIPTION
Use this command to add one or more members to an existing zone configuration.
This command changes the Defined Configuration. For the change to take effect, enable the
configuration with the cfgEnable command. For the change to be preserved across switch reboots, save
the configuration to nonvolatile memory with the cfgSave command.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
When an FCS policy is enabled, this command can be issued only from the primary FCS switch.
OPERANDS
The following operands are required:
"cfgName"
Specify a name for the zone configuration, enclosed in double quotation marks.
"member"
Specify a zone member or a list of zone members to be added to the
configuration. The list must be enclosed in double quotation marks. Members
must be separated by semicolons.
EXAMPLES
To add two new zones to the configuration "Test_cfg":
switch:admin> cfgadd "Test_cfg", "greenzone;bluezone"
SEE ALSO
,