Dell POWEREDGE M1000E User Manual
Page 820
792
Fabric OS Command Reference
53-1002746-01
portShow
2
Online
Up and running.
Offline
Not online, see portPhys for more detail.
Testing
Running diagnostics.
Faulty
Failed diagnostics.
Persistently Disabled
Persistently disabled.
Protocol
Protocol used by the port: FC or FCoE.
portPhys
The port's physical state:
No_Card
No interface card present.
No_Module
No module (GBIC or other) present.
No_Light
Module is not receiving light (Condor 2 ports only).
No_SigDet
No signal detected; displays when a quad small form-factor pluggables (QSFPs)
is installed without cables).
Mod_Inv
Incompatible vendor or module speed mismatch.
No_Sync
Receiving light but out of sync.
In_Sync
Receiving light and in sync.
Laser_Flt
Module is signaling a laser fault.
Port_Flt
Port marked faulty.
Diag_Flt
Port failed diagnostics.
Lock_Ref
Locking to the reference signal.
portScn
The port's last State Change Notification.
port generation number
The port's generation number for the last offline state change.
portId
The port's 24-bit port ID.
portIfId
The user port's interface ID.
portWwn
The port's world wide name.