Dell POWEREDGE M1000E User Manual
Page 892
864
Fabric OS Command Reference
53-1002746-01
portThConfig
2
LR
Link reset
TU
Trunk Utilization
Only the following areas are valid for VE_Ports.
UTIL
Port utilization
PKTLOSS
Packet loss
ST
State change
--set
Configures the Fabric Watch thresholds for monitoring a specified area for all
ports of a specified port type. When configuring a threshold, you must specify a
port type and area. The following operands are optional and valid only with the
--set option. Defaults are used unless you configure custom settings. Defaults
parameters vary depending on the area and platform. Refer to the Fabric Watch
Administrator's Guide for specific details.
-timebase time_base
Specifies the time interval between two samples to be compared. Valid intervals
include the following:
day
Samples are compared once a day.
hour
Samples are compared once every hour.
minute
Samples are compared once every minute.
-highthreshold -value value
Specifies the high threshold value for triggering a specified alert action. To change
the default value, provide an integer value.
-lowthreshold -value value
Specifies the low threshold for triggering a specified alert action. To change the
default value, provide an integer value.
-trigger above | below
Specifies the actions for in range port behavior. In range is defined as the space
above the low threshold and below the high threshold.
-action actions
Specifies the actions triggered by a configured event condition. Valid values
include one or more of the following actions. If more than one action is specified,
the actions must be separated by commas.To change the existing configuration of
actions, you must first issue the command with the none option to reset the
existing configuration, and then reissue the command with the new configuration
of actions.
raslog
Event triggers a RASlog message.
snmp
Event triggers an SNMP trap.
Event triggers an e-mail.