Fcoe – Dell POWEREDGE M1000E User Manual
Page 324
296
Fabric OS Command Reference
53-1002746-01
fcoe
2
fcoe
Manages and displays FCoE configuration.
SYNOPSIS
fcoe --cfgshow [[slot/]port]
fcoe --portcfg [[slot/]port] ve_port | vf_port
fcoe --disable [slot/]port
fcoe --enable [slot/]port
fcoe --loginshow [[slot/]port]
fcoe --fcmapset -vlan vid fcmapid
fcoe --fcmapunset -vlan vid
fcoe --fipcfg -advintvl intvl
fcoe --fipcfgshow
fcoe --resetlogin [-teport [slot/]port | -device wwn]
fcoe --help
DESCRIPTION
Use this command to configure and display the status of FCoE ports, FCoE Initialization Protocol (FIP),
and FCMAP settings.
Unlike regular FC ports, FCoE ports are embedded interfaces that are not directly associated with an
external physical port on the switch. Although show commands such as switchShow display FCoE ports
as "ports," configuration of these ports through the regular FC CLI is disabled. Only the FCoE CLI
commands can be used.
NOTES
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
OPERANDS
This command has the following operands.
slot
Specifies the slot number on bladed systems, followed by a slash (/).
port
Specifies the port number. There are 24 configurable embedded FCoE ports on
the Brocade 8000 switch, and the valid range for port is 8 to 31. On the Brocade
FCoE 10-24 blade, there are 24 configurable FCoE ports numbered 0 to 23. Use
switchShow for a list of valid FCoE ports.
--help
Displays the command usage.
--cfgshow
Displays the configuration of a specified embedded FCoE port. If a port is not
specified, the command displays all port configurations.
--disable
Disables the specified FCoE port.