Fabric OS Command Reference
53-1002746-01
portCfgShow
2
To display the QoS configuration for an EX_Port (QoS over FCR deployment):
switch:admin> switchshow | grep EX-Port
16 16 id N4 Online FC EX-Port \
10:00:00:05:1e:41:4a:45 "Tom_100"
(fabric id = 25 )(Trunk master)
switch:admin> portcfgshow 16
Area Number: 11
Octet Speed Combo: 1(16G|8G|4G|2G)
Speed Level: AUTO(HW)
Fill Word(On Active) 0(Idle-Idle)
Fill Word(Current) 0(Idle-Idle)
AL_PA Offset 13: OFF
Trunk Port ON
Long Distance LS
VC Link Init OFF
Desired Distance 10 Km
Reserved Buffers 86
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
LOS TOV enable OFF
NPIV capability ON
QOS E_Port AE
Port Auto Disable: OFF
Rate Limit OFF
EX Port ON
Mirror Port OFF
Credit Recovery ON
F_Port Buffers OFF
NPIV PP Limit: 126
CSCTL mode: OFF
Fault Delay 1(1.2sec)
D-Port mode: ON
D-Port over DWDM: ON
FEC active
To display an FCIP Tunnel on a Brocade FX8-24 with and without IPSec information (In the following
examples, IPSec is in legacy mode):
switch:admin> portcfgshow fciptunnel 1/12 -ipsec
-------------------------------------------
Tunnel ID: 1/12
Tunnel Description:
Compression: Off
Fastwrite: Off
Tape Acceleration: Off
TPerf Option: Off
IPSec: Enabled (legacy)
IPSec Key: '12345678901234567890123456789012'
QoS Percentages: High 50%, Med 30%, Low 20%
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:52:fe:00
Flags: 0x00000000
FICON: Off