Perfshowalpacrc – Dell POWEREDGE M1000E User Manual
Page 639
Fabric OS Command Reference
611
53-1002746-01
perfShowAlpaCrc
2
perfShowAlpaCrc
Displays the CRC error count by port or by arbitrated loop physical address (AL_PA).
SYNOPSIS
perfshowalpacrc [slot/]port [ALPA]
DESCRIPTION
Use this command to display the cyclic redundancy check (CRC) error count of one or all devices
attached to a port. If the AL_PA operand is specified, only the CRC count for that AL_PA device is
displayed. If the AL_PA operand is not specified, the CRC count for all the AL_PA devices on a specified
port are displayed.
CRC count is a 64-bit counter. The CRC count value is displayed in hexadecimal.
NOTES
This command requires an Advanced Performance Monitoring license.
This command is not supported on virtual FC ports (VE/VEX_Port), EX_Port, M (Mirror) ports and GbE
ports.
The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.
This command is not supported on all platforms. Refer to the Fabric OS Administrator's Guide for specific
hardware support.
OPERANDS
This command has the following operands:
slot
For bladed systems only, specifies the slot number of the port to be displayed,
followed by a slash (/).
port
Specifies the number of the port to be displayed, relative to its slot for bladed
systems. Use switchShow for a list of valid ports.
ALPA
Specify the AL_PA address to get the CRC errors for a specific device. This
operand is optional; if the operand is omitted, this command displays CRC error
counts for all devices attached to the specified port.
EXAMPLES
To display the CRC error count for all AL_PA devices on a port:
switch:admin> perfshowalpacrc 2/4
ALPA CRC_ERROR_COUNT
----------------------------------
0x01 0
0x03 0
SEE ALSO