Fabric OS Command Reference

915

53-1002746-01

secPolicyAdd

2

To add two devices to attach to domain 3, ports 1 and 3, in an existing empty DCC policy; the port WWN
of the first device is 11:22:33:44:55:66:77:aa and port WWN of the second device is
11:22:33:44:55:66:77:bb:

primaryfcs:admin> secpolicyadd "DCC_POLICY_abc", \
"11:22:33:44:55:66:77:aa;11:22:33:44:55:66:77:bb;3(1,3)"
Member(s) have been added to DCC_POLICY_abc.

To add a security policy:

switch:admin> secpolicyadd SCC_POLICY,\
"10:00:00:05:1e:a3:01:d9" -legacy
switch:admin> secpolicyshow
________________________________________
ACTIVE POLICY SET
________________________________________
DEFINED POLICY SET
SCC_POLICY
WWN DId swName
-------------------------------------
10:00:00:05:1e:a1:ef:b9 2 sw0
10:00:00:05:1e:a3:00:59 5 sw0
10:00:00:05:1e:a2:f9:09 3 sw0
10:00:00:05:1e:a3:01:d9 3 sw0