Dell POWEREDGE M1000E User Manual
Page 121
Fabric OS Command Reference
93
53-1002746-01
bpPortLoopbackTest
2
8
Runs test at 8 Gbps (Default for Condor2).
16
Runs test at 16 Gbps (Condor3 only).
-bpports itemlist
Specifies a list of blade ports to test. By default all valid blade ports in the specified
blade are tested. On the Brocade Encryption platforms, ports 80-103 are the only
valid ports, because these are the only blade ports with access to the Vader chip.
Refer to the itemList help page for further information on the itemlist parameter.
DIAGNOSTICS
When it detects failures, the test may report one or more of the following error messages. If errors
persist, contact Technical Support.
DATA
Data received does not match the data sent.
ERRSTAT
Errors were found in the ASIC statistics.
INIT
Port failed to initialize.
PORTDIED
A previously initialized port went to an un-initialized state.
STATS
Errors were found in the ASIC statistics.
TIMEOUT
Did not receive a frame in the given timeout period.
XMIT
Frame transmission failure.
EXAMPLES
To run the test on blade ports 80-90 with one frame:
switch:admin> bpportloopbacktest -bpports 80-90 -nframes 1
Running bpportloopbacktest ..............
Ram Init
Ob1 portloopbacktest on ports 80-90 lbMode 7 speed 4
Info: Vader port 0 recovering Rx Fifo
Info: Vader port 1 recovering Rx Fifo
Info: Vader port 2 recovering Rx Fifo
Info: Vader port 3 recovering Rx Fifo
Info: Vader port 4 recovering Rx Fifo
Info: Vader port 5 recovering Rx Fifo
Ob1 portloopbacktest on ports 80-90 PASSED
Test Complete: bpportloopbacktest Pass 1 of 1
Duration 0 hr, 0 min & 24 sec (0:0:24:599).
Cleaning up after test.......
passed.