Dell POWEREDGE M1000E User Manual
Page 828
800
Fabric OS Command Reference
53-1002746-01
portShow
2
192.168.12.103 255.255.255.255 * 0 U C (crossport)
192.168.12.201 255.255.255.255 * 0 U H L (crossport)
192.168.21.0 255.255.255.0 * 0 U C (crossport)
192.168.21.103 255.255.255.255 * 0 U C (crossport)
192.168.21.201 255.255.255.255 * 0 U H L (crossport)
To display the ARP tables on the Brocade 7800:
switch:admin> portshow arp ge0
Port: ge0
IP Address Mac Address Flags
------------------------------------------------------
192.168.0.10 00:05:1e:c3:f0:1a Resolved
192.168.0.11 00:05:1e:c3:f0:1a Resolved
192.168.0.250 00:00:00:00:00:00
2000::10 00:05:1e:c3:f0:1a Resolved
2000::11 00:05:1e:c3:f0:1a Resolved
2000::1:250 00:00:00:00:00:00
switch:admin> portshow arp ge5
No Arp Entries found
To display the VLAN tagging configurations on a Brocade 7800:
switch:admin> portshow vlantag ge0
Port: ge0
Interface Address VlanId L2CoS Flags
Destination Address
-------------------------------------------------------------------
fe80::205:1eff:feef:2200 55 0 APP
2002:2055::1
fe80::205:1eff:feef:2200 55 0 APP
2002:2050::112
2002:2055::143 55 0 APP
2002:2055::1
2002:2055::143 55 0 Perm
2002:2050::112
To display the atuo-negotiation of 1GbE port:
switch:admin> portshow autoneg 1/ge2
Auto-Negotiation Configuration:
Port: 1/ge2
Auto-Negotiate: Enabled
FUNCTION
Display FCIP tunnels, circuits, management interfaces and FICON statistics on the Brocade
7800/FX8-24
SYNOPSIS
portshow option [all | [slot/]ve_port]] arguments [optional_arguments]