Dell POWEREDGE M1000E User Manual
Page 1039
Fabric OS Command Reference
1011
53-1002746-01
switchShow
2
LS Attributes
On a switch in Virtual Fabric mode, this field displays logical switch attributes,
including the fabric ID associated with the logical switch, the switch role (default
switch or base switch), and the fabric Address Mode (0, 2 or 3). If Virtual Fabrics
are disabled, only the Address Mode is displayed. The fabric Address Mode value
is set by the configure command (Enable a 256 Area Limit).
The switch summary is followed by one-line description for non-EX_Ports and one or two lines for
EX_Ports:
Index
Port index is a number between 0 and the maximum number of supported ports
on the platform. The port index identifies the port number relative to the switch.
Slot
Slot number; 1-12.
Port
Port number; 0-15, 0-31, or 0-63.
Address
The 24-bit Address Identifier.
Media
Media types include the following:
--
No module present. Applicable to all port types.
cu
Displays when the copper (default) GbE port ge0 or ge1 is active (refer to
portCfgGeMediaType for more information). If the optical GbE port is active and
an SFP is installed (copper or optical), "id" is displayed. If nothing is installed on
the optical port, the Media field shows "--". The "cu" field also displays for
interchassis links (ICLs).
id
Serial ID. Indicates that an SFP is installed. Use sfpShow to get more information
about the SFP, including the serial number.
Speed
The speed of the port. Valid port speeds include the following:
1G
1 Gbps fixed transfer speed (not supported on 16 Gbps-capable ports)
N1
1 Gbps negotiated transfer speed (not supported on 16 Gbps-capable ports)
2G
2 Gbps fixed transfer speed (only supported with use of 8 Gbps SFPs)
N2
2 Gbps negotiated transfer speed (only supported with use of 8 Gbps SFPs)
4G
4 Gbps fixed transfer speed
N4
4 Gbps negotiated transfer speed
8G
8 Gbps fixed transfer speed
N8
8 Gbps negotiated transfer speed