Nsshow – Dell POWEREDGE M1000E User Manual
Page 593
Fabric OS Command Reference
565
53-1002746-01
nsShow
2
nsShow
Displays local Name Server (NS) information.
SYNOPSIS
nsshow [-r][-t]
DESCRIPTION
Use this command to display local NS information about devices connected to a switch. If no information
is available for the switch, the command displays the following message: "There is no entry in the Local
Name Server."
Use nsAllShow to display NS information for all switches in the fabric.
Each line of output displays the following information:
Type
Displays U for unknown, N for N_Port, NL for NL_Port.
PID
Displays the 24-bit Fibre Channel address of the device.
COS
Displays the Class of Service levels supported by the device. This can be class 1,
class 2, or class 3. The command displays only the numeric values, 1, 2, and/or 3.
A device can support multiple CoS levels.
PortName
Displays the device port world wide name (WWN).
NodeName
Displays the device node WWN.
TTL
Displays the time-to-live, in seconds, for cached entries or NA (not applicable) if
the entry is local.
SCR
Displays the state change registration of the device. This field displays only with
the -r option.
Device type
Displays the device type if -t is specified.
Fabric Port Name
Displays the F_Port WWN to which the N_Port connects.
Permanent Port Name
Displays the physical N_Port or NL_Port WWN.
Port Index
Displays the index number of the physical N_Port to which the device connects.
Share Area
Displays "Yes" if the port shares an area; otherwise displays "No".
Device Shared in Other AD
Displays "Yes" if the device is shared in another Admin Domain; otherwise
displays "No."
Redirect
Displays "Yes" if the device is involved in frame redirection; otherwise displays
"No". The device involved in frame redirection is specified as either "virtual" ,
"host", or "target".