Dell POWEREDGE M1000E User Manual
Page 114
86
Fabric OS Command Reference
53-1002746-01
bottleneckMon
2
VC
Specifies the Virtual Channel number. The valid range is 1 trough 31. VC 0 is
invalid.
--linkreset slot/blade_port
Performs a link reset on the specified front-end or back-end blade port. The blade
port number can be located in the "Bpt" column output of the bladePortMap
command. The bladeportmap command requires root permissions.
--showcredittools
Displays the backend port credit recovery configuration as enabled or disabled. In
addition, the output indicates whether link reset mode or link reset threshold mode
is configured.
--help
Displays the command usage.
EXAMPLES
Bottleneck detection examples
To enable bottleneck detection on the switch without alerts (statistics collected with default parameters
are still available for viewing):
switch:admin> bottleneckmon --enable
To enable bottleneck detection on the switch with congestion and latency alerts using default values for
thresholds and time (preferred use case):
switch:admin> bottleneckmon --enable -alert
To enable bottleneck detection on the switch with congestion alerts only:
switch:admin> bottleneckmon --enable -alert=congestion
To enable bottleneck detection on the switch with latency alerts only:
switch:admin> bottleneckmon --enable -alert=latency
To customize congestion bottleneck detection on a port range after default alerts are enabled
switch-wide:
switch:admin> bottleneckmon --enable -alert
switch:admin> bottleneckmon --config -alert \
-cthresh .5 -time 240 1-15
To change the bottleneck detection configuration on the logical switch to allow congestion alerts only:
switch:admin> bottleneckmon --config -alert=congestion
To change the bottleneck detection configuration on the logical switch to allow latency alerts only:
switch:admin> bottleneckmon --config -alert=latency
To change the bottleneck detection configuration on the logical switch to allow both congestion and
latency alerts:
switch:admin> bottleneckmon --config -alert
To change the bottleneck detection configuration on the logical switch to disable all alerts:
switch:admin> bottleneckmon --config -noalert