Dell POWEREDGE M1000E User Manual
Page 825
Fabric OS Command Reference
797
53-1002746-01
portShow
2
To display an FCoE port:
switch:admin> portshow 8
portIndex: 8
portName:
portHealth: HEALTHY
Authentication: None
portDisableReason: None
portCFlags: 0x1
portFlags: 0x2cb03 PRESENT ACTIVE F_PORT G_PORT U_PORT\
LOGICAL_ONLINE LOGIN NOELP LED NSREG ACCEPT FLOGI
portType: 17.0
POD Port: Port is licensed
portState: 1 Online
Protocol: FCoE
portPhys: 6 In_Sync portScn: 32 F_Port
port generation number: 0
state transition count: 1
portId: 850800
portIfId: 43020028
portWwn: 20:08:00:05:1e:76:60:80
portWwn of device(s) connected:
Distance: normal
portSpeed: 10Gbps
FUNCTION
Display IP Interface configurations on the Brocade 7800/FX8-24 platforms
SYNOPSIS
portshow option [slot/]ge_port [optional_args]
DESCRIPTION
Use this command to display FCIP-related configuration parameters on the Brocade 7800 switch and on
the Brocade FX8-24 blade. The parameters displayed by this command are set with the portCfg
command. The following displays are supported with this command:
•
portshow ipif - Displays the local IP interfaces.
•
portshow iproute - Displays static routes on the IP interface.
•
portshow arp - Displays the content of the address resolution protocol (ARP) table.
•
portshow vlantag - Displays the IP interface VLAN configuration.
•
portshow autoneg - Displays autonegotiation status.
NOTES
IPv6 addresses are supported.
OPERANDS
This command has the following operands:
slot
For bladed systems only, specifies the slot number of the port to be displayed,
followed by a slash (/).
ge_port
Specifies the number of the GbE port to be displayed relative to the slot number.
The GbE ports are numbered ge0 - ge9 on the Brocade FX8-24 blade and ge0 -
ge5 on the Brocade 7800 switch. The 10GbE ports on the Brocade FX8-24 blade
are numbered xge0 and xge1. Use the switchShow command for a listing of valid
ports