Dell POWEREDGE M1000E User Manual
Page 1040
1012
Fabric OS Command Reference
53-1002746-01
switchShow
2
10G
10 Gbps fixed transfer speed
N10
10 Gbps negotiated transfer speed
16G
16 Gbps fixed transfer speed
N16
10 Gbps negotiated transfer speed
AN
Autonegotiating
UN
Unknown
State
Port state information. Valid states include the following:
No_Card
No interface card present.
No_Module
No module (GBIC or other) present.
Mod_Val
Module validation in process.
Mod_Inv
Module speed mismatch or incompatible SFP.
No_Light
The module is not receiving light. This state is not applicable to Condor 3-based
interchassis link (ICL) ports.
No_SigDet
No signal is detected on the port. For Condor 3-based interchassis link (ICL)
ports, this state replaces the No_Light indicator. It indicates that a quad small
form-factor pluggable (QSFP) has been installed but is not connected with a
cable.
No_Sync
The module is receiving light but is out of sync.
In_Sync
The module is receiving light and in sync.
Laser_Flt
The module is signaling a laser fault.
Port_Flt
The port is marked faulty.
Diag_Flt
The port failed diagnostics.
Lock_Ref
The port is locking to the reference signal.
Testing
The port is running diagnostics.
Offline
A port connection is not established (for virtual ports only).