beautypg.com

Portcfglosstov – Dell POWEREDGE M1000E User Manual

Page 717

background image

Fabric OS Command Reference

689

53-1002746-01

portCfgLossTov

2

portCfgLossTov

Enables or disables de-bouncing of signal loss for front end ports.

SYNOPSIS

portcfglosstov [slot/]port mode

DESCRIPTION

Use this command to enable or disable the de-bouncing of loss of signal for 100 ms for front end ports.
Use portCfgShow to display the current setting.

If executed without operands, the command prints the usage.

NOTES

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

On a chassis, this command must be executed on the active CP.

OPERANDS

This command has the following operands:

slot

For bladed systems only, specifies the slot number of the port to be configured,
followed by a slash (/).

port

Specifies the port to be configured, relative to its slot for bladed systems. Use
switchShow to list valid ports.

mode

Specify 1 to enable the configuration. Specify 0 to disable the configuration.

EXAMPLES

To enable the configuration on port 1/5 and to display the configuration:

switch:admin> portcfglosstov 1/5 1

switch:admin> portcfgshow 1/5
Area Number: 5
Speed Level: AUTO(HW)
Fill Word(On Active): 0(Idle-Idle)
Fill Word(Current): 0(Idle-Idle)
AL_PA Offset 13: OFF
Trunk Port ON
Long Distance OFF
VC Link Init OFF
Locked L_Port OFF
Locked G_Port OFF
Disabled E_Port OFF
Locked E_Port OFF
ISL R_RDY Mode OFF
RSCN Suppressed OFF
Persistent Disable OFF
LOS TOV enable ON
(Output truncated)

To disable the configuration on port 1/5:

switch:admin> portcfglosstov 1/5 0

SEE ALSO

portCfgShow