beautypg.com

Thmonitor – Dell POWEREDGE M1000E User Manual

Page 1084

background image

1056

Fabric OS Command Reference

53-1002746-01

thMonitor

2

thMonitor

Enables monitoring of small form-factor pluggables (SFPs).

SYNOPSIS

thmonitor --enable brcdsfp

thmonitor --disable brcdsfp

thmonitor --show

DESCRIPTION

Use this command to enable Fabric Watch threshold monitoring for 10G and 16G SFPs and for 16G
QSFPs. Fabric Watch does not monitor 10G and 16G SFPs or 16G QSFPs unless monitoring is explicitly
enabled with this command.

NOTES

This command requires a Fabric Watch license.

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

OPERANDS

This command has the following operands:

--enable brcdsfp

Enables Fabric Watch threshold monitoring for 10G and 16G SFPs and for 16G
QSFPs. The feature is by default disabled.

--disable brcdsfp

Disables Fabric Watch threshold monitoring for 10G and 16G SFPs and for 16G
QSFPs.

--show

Displays the current configuration.

--help

Displays the command usage.

EXAMPLES

To enable Fabric Watch threshold monitoring for 10G and 16G SFPs and for 16G QSFPs.

switch:admin> thmonitor --enable brcdsfp
Brcd SFP Threshold Monitoring is enabled

To display the configuration:

switch:admin> thmonitor --show
Brcd SFP Threshold Monitoring is enabled

To disable Fabric Watch threshold monitoring for 10G and 16G FPs and for 16G QSFPs.

switch:admin> thmonitor --disable brcdsfp
Brcd SFP Threshold Monitoring is disabled

SEE ALSO

thConfig

,

sfpShow