Fabric OS Command Reference
1039
53-1002746-01
sysMonitor
2
-action actions
Specifies the actions triggered by a configured event condition. Valid values
include one or more of the following actions. If more than one action is specified,
the actions must be separated by commas. To change the existing configuration
of actions, you must first issue the command with the none option to reset the
existing configuration, and then reissue the command with the new configuration
of actions.
snmp
Event triggers an SNMP trap.
raslog
Event triggers a RASlog message.
Event triggers an e-mail.
none
Event triggers no action.
-buffer value
Specifies the buffer value for in-range behavior. A buffer defines a zone within
which event criteria are met, rather than a single threshold value. This operand is
optional with the -trigger options and valid only with these options.
-nosave
Prevents the configuration changes from being saved persistently. This option
allows you to make and view changes without overwriting the saved configuration.
When you use --config with the -nosave option and the switch reboots your
changes will be lost.
--apply
Applies the custom or default configuration for thresholds, actions, or both. This
command allows you to choose between custom and default settings. The
specified configuration takes effect upon execution of this command. When you
select custom, the saved configuration becomes effective.
--cancel
Cancels a nonpersistent configurations. This command effectively undoes the
-nosave operation without reboot.
You must always specify a class and area when you apply or cancel a
configuration. Thresholds and alarm levels are optional; if omitted, all
nonpersistent configurations for the specified class and area are used.
--pause | --continue arguments
Pauses or resumes monitoring. The following arguments are required:
class
Specifies the class.
-area area[,area]... | all
Specifies the area. You can either specify one or more areas separated by a
comma, or you can specify all to indicate all areas.
-index index | all
Specifies the index number for the element to be monitored, or specify -index all
to indicate all elements. An element is a subcomponent of an area, for example, a
temperature sensor on the switch.
--show
Displays the Fabric Watch configuration for the specified class. When used
without operands, this command displays the current Fabric Watch configuration
for all classes and areas. When used with optional arguments, the output displays
partial views or status information.