Dell POWEREDGE M1000E User Manual
Page 400
372
Fabric OS Command Reference
53-1002746-01
ficonShow
2
To display the local RLIR database:
switch:user> ficonshow RLIR
{
{Fmt Type PID Port Incident Count TS Format Time Stamp
0x18 N 502e00 46 1 Time server Mon Jan 13 04:29:33 2003
Port Status: Link not operational
Link Failure Type: Loss of signal or synchronization
Registered Port WWN Registered Node WWN Flag Node Parameters
50:05:07:64:01:40:0f:ca 50:05:07:64:00:c1:69:ca 0x50 0x200105
Type Number: 002064
Model Number: 101
Manufacturer: IBM
Plant of Manufacture: 02
Sequence Number: 0000000169CA
tag: 2e00
Switch Port WWN Switch Node WWN Flag Node Parameters
20:2e:00:60:69:80:1e:4e 10:00:00:60:69:80:1e:4e 0x00 0x200a2e
Switch Part Number: 060-0001501-05
Switch Serial Number: 0FT02X801E4E
Domain: 20480
}
}
The local RLIR database has 1 entry.
To display the local ILIR database:
switch:user> ficonshow ILIR
{
{FRU Failure [2]: Power Supply[2] failure occurred \
on Mon Jan 13 12:11:38 2003
Fmt Protocol Domain Fabric WWN Switch WWN
0x18 FICON 80 10:00:00:60:69:33:33:33 10:00:00:60:69:80:1e:4e
FRU part number: 23000000602
FRU serial number: FL2L0001071
{Listener Port Type Listener PID Listener Port WWN
N 0x502b00 50:05:07:64:01:00:15:8d
}
}
{FRU Failure [3]: Power Supply[4] failure occurred \
on Mon Jan 13 12:11:38 2003
Fmt Protocol Domain Fabric WWN Switch WWN
0x18 FICON 80 10:00:00:60:69:33:33:33 10:00:00:60:69:80:1e:4e
FRU part number: 23000000602
FRU serial number: FL2L0001060
{Listener Port Type Listener PID Listener Port WWN