Fabric OS Command Reference

709

53-1002746-01

portCfgShow

2

Locked L_Port

Displays ON when the port is locked to L_Port only. Displays (..) or OFF when
L_Port lock mode is disabled and the port behaves as a U_Port). This value is set
by the portCfgLport command.

Locked G_Port

Displays ON when the port is locked to G_Port only. Displays (..) or OFF when
G_Port lock mode is disabled and the port behaves as a U_Port. This value is set
by the portCfgGport command.

Disabled E_Port

Displays ON when the port is not allowed to be an E_Port. Displays (..) or OFF
when the port is allowed to function as an E_Port. This value is set by the
portCfgEport command.

ISL R_RDY Mode

Displays ON when ISL R_RDY mode is enabled on the port. Displays (..) or OFF
when ISL R_RDY mode is disabled. This value is set by the portCfgISLMode
command.

RSCN Suppressed

Displays ON when RSCN suppression is enabled on the port. Displays (..) or OFF
when RSCN suppression is disabled. This value is set by the portCfg rscnsupr
command.

Persistent Disable

Displays ON when the port is persistently disabled; otherwise displays (..) or OFF.
This value is set by the portCfgPersistentDisable command.

LOS TOV enable

Displays ON when LOS TOV is enabled on the port; otherwise displays (..) or
OFF. This value is set by the portCfgLossTov command.

NPIV capability

Displays ON when N_Port ID Virtualization (NPIV) is enabled on the port (default).
Displays (..) or OFF when NPIV capability is disabled. This value is set by the
portCfgNPIVPort command.

QOS E_Port

Displays ON when Quality of Service (QoS) is enabled on the E_Port (or EX_Port)
when QoS is enabled in an FCR deployment scenario. Displays (..) or OFF when
QoS is disabled. By default, QoS is enabled if sufficient buffers are available.
Displays AE when QoS is configured as Auto Enabled. In the AE state, QoS is
enabled based on the availability of buffers.

Use islShow to determine the current status of QoS (on or off) in the AE state.
This value is set by the portCfgQos command.

EX_Port

Displays ON when the port is configured as an EX_Port. Otherwise displays (..) or
OFF. This value is set by the portCfgExPort command.

Mirror Port

Displays ON when Mirror Port is enabled on the port. Displays (..) or OFF when
Mirror Port is disabled. This value is set by the portCfg mirrorport command.

FC Fastwrite

Displays ON when FC FastWrite is enabled on the port or (..) or OFF when
disabled. FastWrite is disabled by default. This value is set by the portCfg
fastwrite
FC Fastwrite is no longer supported as of Fabric OS v7.0.0.