beautypg.com

Dell POWEREDGE M1000E User Manual

Page 283

background image

Fabric OS Command Reference

255

53-1002746-01

errDump

2

NOTES

The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in
place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for
details.

OPERANDS

This command has the following operands:

--all

Displays messages for the entire chassis for a user with admin and chassis
permissions. This operand is optional; if omitted, the messages for the current
logical switch context are displayed.

--count number

Displays messages based on count value.

--reverse

Displays messages in reversed order. This operand is optional; if omitted, the
messages display in chronological order.

--severity severity

Displays messages based on severity.

0

Displays critical, error, warning, and informational messages.

1

Displays critical messages.

2

Displays error messages.

3

Displays warning messages.

4

Displays informational messages.

--slot slotnum

Displays messages based on slot.

--attributes attribute

Displays messages with the given attribute. Valid attributes values are 0(ALL) and
1(FFDC).

--message msgID

Displays all raslog messages based on the message ID.

--help

Displays command usage.

EXAMPLES

To display the error log for the chassis:

switch:admin> errdump --all
Fabric OS: v7.0.0

2010/12/17-22:29:17, [SEC-1203], 9036, CHASSIS, INFO,\
Spir_67, Login information : Login successful via \
TELNET/SSH/RSH. IP Addr: 10.106.7.62

2010/12/17-22:29:17, [ZONE-1022], 9037, CHASSIS, INFO, \
Spir_67, The effective configuration has changed to meh.

2010/12/17-22:29:17, [FABR-1001], 9041, CHASSIS, WARNING, \