Rockwell Automation 5370-CVIM2 Module User Manual
Page 503

5
Chapter
Chapter 10
Environment Menu Selections
10–17
When
Freeze Last Rejects
is selected, the first rejected image will be
held on the display. While the image is frozen, subsequent rejected
images will be stored in the reject queue. Once the queue is full, the
oldest rejected image in the queue will be removed from the queue and
placed on display (in effect, an automatic resume when the queue is full).
When you select
Resume
, the CVIM2 will resume the normal image
display if the reject queue is empty; otherwise, the next image in the
queue will be removed from the queue and displayed.
Resume
When you pick
Resume
in the image display menu bar, or pick the
button in the
Freeze Modes
panel, a “frozen” image is released, and the
image updates resume.
Reject Queue Size
This field reflects the reject queue size that was selected in the
Display
panel, as indicated in Chapter 4, Inspection Configuration, on page 4–17.
Rejects Held
This field reflects the current number of reject images held in the CVIM2
system. This number, in some instances, may be one greater than the queue
size.
Inspection Results Display Panel
The main purpose of the inspection results panel is to display the results of
each inspection cycle for each tool in the associated tool set. The panel
displays the tool’s name, the pass/fail status of the previous inspection, the
cumulative total of failed inspections, and the results values of the previous
inspection. (Note: This panel is the same for both online and offline
(“setup”) operations.)
The basic display data are illustrated by the example
Results
panel shown in
Figure 10.19 (page 10–18).