Chapter 6
Reference Tools
6–32
To save a feature image, pick the
button. When you do, the keyboard
panel appears with this instruction in the title bar:
Enter a file name. Default device is MC:.
To store an image file in the default device, enter a file name such as . . .
feature1
To store an image in a different device, enter the device name, a colon, and a
file name, such as . . .
EE:feature1
In all cases, after entering the appropriate image name in the keyboard panel,
pick the
key. When you do, the CVIM2 system begins saving the
subimage and displays this message:
Saving Image
Please Wait
When the CVIM2 system finishes saving the image, it displays this message:
Done saving image
Compression ratio 2:1
The compression ratio value appearing in the message is truncated; thus, 2:1
could actually be 2.9:1. Also, the actual compression ratio value varies with
the details in the feature image, but in any case it cannot exceed the
theoretical limit of 4:1 (for lossless compression).
After two or three seconds, the “Done” message disappears and the
Image
Manager
panel reappears. Pick the
button to exit back to the tool edit
panel.
When the tool edit panel reappears, as shown in Figure 6.27, note that the
new feature image name now appears in the
Image Name
field, and all of
the fields and buttons are now active.
Figure 6.27 Example: Tool Edit Panel After Configuring and Selecting a Feature Image