beautypg.com

Ethernet glossary, Ethernet glossary -105 – Altera Low Latency 40-Gbps Ethernet MAC and PHY MegaCore Function User Manual

Page 150

background image

Addr

Name

Bit

Description

HW Reset

Value

Access

0xB05

RX_PTP_CLK_

PERIOD

[19:0]

clk_rxmac

clock period.

Bits [19:16]: nanoseconds
Bits [15:0]: fraction of nanosecond

This value is

set to the

correct clock

period for the

required RX

MAC clock

frequency.

The clock

period is

different for

40GbE

variations and

100GbE

variations.

RW

Related Information

1588 Precision Time Protocol Interfaces

on page 3-38

PTP Transmit Functionality

on page 3-43

Ethernet Glossary

Table 3-32: Ethernet Glossary

Provides definitions for some terms associated with the Ethernet protocol.

Term

Definition

BIP

Bit Interleaved Parity. A diagonal parity field which is carried in the periodic

alignment markers on each virtual lane, allowing isolation of a bit error to a

physical channel.

CAUI

100 gigabit attachment unit interface. (C is the symbol in Roman Numerals for

100). This is an electrical interface that which is based on a 10-lane interface with

a bandwidth of 10 Gbps per lane. (In this implementation, the PMA multiplexes

the 20 PCS lanes into 10 physical lanes.

CGMII

100 gigabit media independent interface. (C is the symbol in Roman Numerals

for 100). This is the byte-oriented interface protocol that connects the PCS and

MAC.

DIC

Deficit Idle Counter. A rule for inserting and deleting idles as necessary to

maintain the average IPG. The alternative is to always insert idles which could

lead to reduced bandwidth.

FCS

Frame Check Sequence. A CRC-32 with bit reordering and inversion.

UG-01172

2015.05.04

Ethernet Glossary

3-105

Functional Description

Altera Corporation

Send Feedback

This manual is related to the following products: