beautypg.com

Tx statistics registers – Altera Low Latency 40-Gbps Ethernet MAC and PHY MegaCore Function User Manual

Page 137

background image

Addr

Name

Bit

Description

HW Reset

Value

Access

the TX MAC to pause outgoing traffic on the

TX Ethernet link. If you implement priority-

based flow control, the TX MAC pauses

outgoing traffic from the indicated priority

queue to the TX Ethernet link in response to

this notification. If you implement standard

flow control, the TX MAC pauses outgoing

traffic on the TX Ethernet link in response to

this notification only if bit [0] of the

TX_XOF_

EN

register has the value of 1.

0x706

RX_PAUSE_

FWD

[0]

cfg_fwd_ctrl

bit. When this bit has the

value of 1, the RX MAC forwards matching

pause frames to the RX client interface.

When this bit has the value of 0, the RX MAC

does not forward matching pause frames to

the RX client interface. In both cases, the RX

MAC forwards non-matching pause frames

to the RX client interface.

1'b0

RW

0x707

RX_PAUSE_

DADDRL

[31:0]

RX_PAUSE_DADDRL

contains the 32 least

significant bits of the destination address for

pause frame matching.

RX_PAUSE_DADDRH

contains the 16 most

significant bits of the destination address for

pause frame matching.
When pause frame processing is turned on, if

{RX_PAUSE_DADDRH[15:0],RX_PAUSE_

DADDRL[31:0]}

matches the incoming pause

frame destination address, the IP core

processes the pause frame. if there is no

match, the IP core does not process the pause

frame.

{RX_PAUSE_DADDRH[15:0],RX_PAUSE_

DADDRL[31:0]}

can be a broadcast,

muilticast, or unicast address.

0xC200_0001 RW

0x708

RX_PAUSE_

DADDRH

[15:0]

0x0180

RW

Related Information

Pause Control and Generation Interface

on page 3-30

Describes the pause signals available in the Low Latency 40-100GbE IP core.

TX Statistics Registers

The TX statistics registers count TX Ethernet traffic and errors. The 64-bit statistics registers are designed

to roll over, to ensure timing closure on the FPGA. However, these registers should never roll over if the

3-92

TX Statistics Registers

UG-01172

2015.05.04

Altera Corporation

Functional Description

Send Feedback

This manual is related to the following products: