Hydraulic controls, About station hydraulics – MTS Series 793 User Manual
Page 307
4. Make sure all test setup prerequisites are complete:
•
All tuning, calibration, etc. is complete.
•
Set up error and limit detectors
•
If required, perform a shunt calibration check.
•
Configure the outgoing program signal.
•
Configure any digital inputs and outputs.
5. Apply Hydraulics
If necessary, override interlocks
6. Install the specimen
•
Manual Control
•
Auto-Offset
•
Manual Offset
7. Load a test (select a program command) from the following sources:
•
The Function Generator
•
The Basic TestWare application
•
The MultiPurpose TestWare application
•
External programming
8. Start the Test.
Run/Stop/Pause Control
9. Adjust the setpoint and span during a test.
Hydraulic Controls
About Station Hydraulics
A hydraulic power unit (HPU) provides hydraulic pressure while a hydraulic service manifold (HSM) controls
the application of HPU pressure to the test station.
Station controls
Typically, the Station Manager window’s Station Controls panel has both HPU and HSM controls.
•
On test systems that use house hydraulic power, the Station Controls panel may have just HSM controls.
•
On some small test systems without an HSM, the Station Controls panel may have just HPU controls.
MTS Series 793 Control Software 307
Using Station Manager to Run Tests