About the shutdown recorder – MTS Series 793 User Manual
Page 138

Description
Item
Enter letters or full words into this field to limit the list of available
signals.
List Filter
Lists the signals available for data acquisition.
Available list
Lists the signals selected for data acquisition.
Included list
Enter the amount of time between points in sec, hr, min, or mSec.
Maximum: 1 second.
Time Between Points
Enter a rate between 1–1024 Hz.
Sample Rate
Define the total number of samples to be recorded. Maximum: 61,440
Total Samples
Maximum: 61,440
Post-trigger Samples
Define the amount of time the recorder runs after shutdown.
Maximum: 60 seconds
Total Duration
Post-trigger Duration
Maximum: 60 seconds
About the Shutdown Recorder
With the Shutdown Recorder, you can capture and analyze data surrounding an unexpected shutdown.
Shutdown data is stored in volatile processor memory.
If a station unloads due to an application crash, data is retrieved by reloading the station, provided the system
is in a proper state. The Shutdown Recorder will not record data in the event of a power loss or a digital
supervisor application crash.
Memory considerations
Your controller must have a minimum of 64 MB of physical memory to use the Shutdown Recorder. You can
purchase a PMC flash module for non-volatile storage of shutdown data.
138 MTS Series 793 Control Software
Station Manager Application