C-Stop Tab

This tab allows the user to configure C-Stop interlock parameters. Configuration access level is required to
edit settings on this tab.

Access

Tools menu > Channel Options > Channel Options window > C-Stop tab

Description

Item

Select number of C-Stop interlocks. The equivalent number of C-Stop tabs will
be displayed, allowing discrete settings for each C-Stop.

Number of C-Stops

Global C-Stop Enable check box. Enables defined C-Stop actions.

C-Stop Enable

Enter a display name for the selected C-Stop. The name entered in this field will
be displayed on the Station Controls panel and in the system actions list.

Name

Select this check box to display a button for the selected C-Stop on the Station
Controls panel.

Enable on Station
Controls

Displays a list of available channels.

Channel

Use the drop down list to define the behavior of the C-Stop for each selected
channel. Select Hold at Level or one of the Ramp To Level options.

Behavior

Select the channel’s active control mode for the controlled stop.

Control Mode

Allows Program Stop to complete before initiating C-Stop defined behavior.

Wait for Program Stop

Select this check box if the channel output might be unstable when a C-Stop is
asserted.

Zero Output

The target end level. Only available for Ramp To Level behaviors.

Target

The amount of time to complete the ramp to the specified target end level (used
with Ramp To Level-Time).

Ramp Time

The rate of the ramp (in units/second) to the target end level (used with Ramp
To Level-Rate.)

Ramp Rate (Units/s)