About program outputs – MTS Series 793 User Manual
Page 229

Note:
To edit any item requires Tuning access level (or higher.)
Conditioner Tab Settings for Three-Stage Valve Drivers
Description
Item
(Model 494.16 VD/DUC only) Sets AC excitation frequency that the
conditioner applies to the servovalve’s sensor spool.
Excitation Frequency
Sets the amount of peak AC excitation that the conditioner applies to
the servovalve’s sensor spool.
Excitation (peak)
Sets the phase for the demodulation circuitry that receives the sensor’s
output.
Phase
The sensor’s output rides on the conditioner’s excitation signal, which
is an AC signal. An optimal phase shift yields the maximum DC output
from the conditioner.
Sets the offset applied by the conditioner to the sensor’s output signal.
Offset
Sets the amount of gain applied by the conditioner to the sensor’s
output signal.
Gain
Gain values affect tuning settings and the noise sensitivity of the valve
command.
Sets the polarity of the spool output or inner loop output signal to
Normal or Invert.
Polarity
Polarity cannot be changed when the station pressure is on.
Calculated Drive Signals Not Assigned Hardware Reference
Access
Station Setup window > navigation pane > Channels > Control Channel n (with calculated output) >
>
Calculated
Calculated Drive Signals Not Assigned Hardware
Description
Item
Specifies the calculated resource(s) that use the drive signal output
of the selected channel.
Calculated
About Program Outputs
Program output channels send analog program commands to external controllers such as the Series 407
Controller and temperature controllers.
MTS Series 793 Control Software 229