7 max. dc-bus current (power recovery) too high, 18 drive dimensioning messages – Lenze DSD User Manual
Page 474

18
Drive dimensioning messages
18.9
Regenerative power supply module
474
Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
18.9.5
Utilisation (supply) relative to the continuous DC-bus current > 100 %
18.9.6
Utilisation relative to the permissible continuous power exceeded
18.9.7
Max. DC-bus current (power recovery) too high
18.9.8
Continuous DC-bus current (power recovery) too high
Warning!
The utilisation of the regenerative power supply module relative to the continuous DC-bus current for sup-
ply is xxx %. Thus the limit value of 100 % is exceeded.
Cause
Effects
Possible remedies
The DC bus current exceeds the per-
missible continuous current of the
drive.
The drive gets too hot and switches
itself off.
Use larger drive.
Warning!
The permissible continuous power of the regenerative power supply module is exceeded. The utilisation
is xxx %.
Cause
Effects
Possible remedies
The DC bus current exceeds the per-
missible continuous current of the
drive.
The drive gets too hot and switches
itself off.
Use larger drive.
Warning!
The utilisation of the regenerative power supply module relative to the max. DC-bus current for power re-
covery is xxx %. Thus the limit value of 100 % is exceeded.
Cause
Effects
Possible remedies
The max. DC-bus current in feedback
operation is higher than the permis-
sible DC-bus current.
The drive is overloaded.
Select larger drive.
Warning!
The utilisation of the regenerative power supply module relative to the continuous DC-bus current for
power recovery is xxx %. Thus the limit value of 100 % is exceeded.
Cause
Effects
Possible remedies
The DC-bus current exceeds the per-
missible continuous current of the
device in feedback operation.
The drive gets too hot and switches
itself off.
Use larger drive.