8 safety coefficient static friction, 9 velocity, 7applications – Lenze DSD User Manual
Page 161

Lenze · Drive Solution Designer · Manual · DMS 4.2 EN · 12/2013 · TD23
161
7
Applications
7.14
Synchronous drive - single roll
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7.14.2.8
Safety coefficient static friction
Conditions
For a reliable power transmission from the drive roll to the material the following conditions have
to be met. Otherwise a warning appears.
• For a motor torque, i. e. F
in
> F
out
:
• For a regenerative torque, i. e. F
in
F
out
:
7.14.2.9
Velocity
Symbol
Description
S
Safety coefficient
• The differential force always has to be smaller than the Static friction to prevent slippage.
The safety coefficient S provides for a safety reserve that can be individually adapted to the
application.
Possible messages
F
in
F
out
-------------
e
μ
0
α
⋅
1
S
100
---------
–
⋅
<
F
out
F
in
-------------
e
μ
0
α
⋅
1
S
100
---------
–
⋅
<
Symbol
Description
v
Speed of the web
• Value is entered in the Motion dimensioning step.